Chat with us, powered by LiveChat

C-Tec XFP501E/CA XFP Single Loop 16 Zone Fire Alarm Control Panel - CAST Protocol

SKU
XFP501E/CA
£306.52 £367.82
Enquire about this product
  • Manufacturer : C-Tec
  • Part Code : XFP501E/CA
  • Single Loop 16 Zone Analogue Addressable Fire Alarm Panel
  • C-Tec CAST Protocol

C-Tec XFP501E/CA Single Loop 16 Zone Fire Alarm Control Panel

The C-Tec XFP501E/CA is a single loop 16 zone XFP fire alarm control panel using the C-Tec CAST protocol.

C-TEC's tried and trusted XFP one loop 16 zone addressable fire alarm panel - now available with C-TEC's own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.

With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices, the installation of a cost-effective, feature-packed addressable fire alarm system has never been easier.

Always thought of the XFP as an entry-level fire panel? Think again. Thanks to CAST's multiple type codes, high speed data transmission and two speedy soft addressing options (automaic via the panel or manually via a handheld programmer/device tester), it is undoubtedly one of the most powerful single loop fire panels around. This, and its ability to sit on a network of up to 8 XFP master panels, makes it ideal for use in small to medium sized stand-alone applications and larger, more sophisticated installations alike.

C-Tec XFP501E/CA XFP Single Loop 16 Zone Fire Alarm Control Panel Technical Specification

  • Approvals/certifications - Certified to EN54-2/4 by the LPCB.
  • Protocol/compatibility - C-TEC CAST.
  • Mains supply - 230V 50/60Hz.
  • Mains rated current - 350mA maximum.
  • Internal power supply - 27Vdc nominal.
  • Total output current limited to - 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).
  • Quiescent current - 50mA (loop unloaded).
  • Max battery size and type - 2 x 12V 3.2Ah VRLA connected in series.
  • No. of loop drivers - 1
  • Max. loop output current - 500mA (40V max)
  • Max. loop length - 1KM.
  • Max. addressable devices per loop - 255
  • No. of conventional sounder circuits - 2 (Max. length per circuit is 500m).
  • EOL resistor value - 6800Ohm 5% Tol. 0/25W (blue, grey, red, gold).
  • Max. sounder output current - 400mA.

We can also offer commissioning services on C-Tec CAST equipment.  Please contact us on 01200 428 410 or sales@thesafetycentre.co.uk for details.

 

Write Your Own Review
You're reviewing:C-Tec XFP501E/CA XFP Single Loop 16 Zone Fire Alarm Control Panel - CAST Protocol
Your Rating

Our Brands

  • Apollo Logo
  • Ctec Logo
  • Electro Detectors Logo
  • Notifier Logo
  • STI Logo
  • Yuasa Logo
  • Apollo Logo
  • Ctec Logo
  • Electro Detectors Logo
  • Notifier Logo
  • STI Logo
  • Yuasa Logo